Synergy H1m Monochromator-Based Multi-Mode Microplate Reader
Synergy™ H1m is the most cost-effective monochromator-based multi-mode microplate reader on the market. Its monochromator optics uses a third generation quadruple grating design that allows working at any excitation or emission wavelength with a 1 nm step. This system supports top and bottom fluorescence intensity, UV-visible absorbance and high performance luminescence detection. It is the ideal system for all the standard microplate applications found in life science research laboratories. Synergy H1m can be turned into a high performance Synergy H1 Hybrid Multi-Mode Microplate Reader with the addition of a filter-based optical module. A dual reagent injection system is available to automate inject/read assays such as ion channels assays or flash luminescence assays (e.g. luciferase or ATP assays).
- Fully monochromator-based with quadruple grating architecture
- Upgradeable to patent-pending Hybrid monochromator-filter optical system
- Compatible with Take3 Multi-Volume Plate: sixteen 2 µL microspots for low volume DNA/RNA 260 nm measurements. Saves precious samples, very fast and simple process.
- High performance fluorescence (top and bottom), absorbance and luminescence detection systems accommodate all life-science research microplate applications.
- Automated Z-height adjustment accommodates variable microplate heights and liquid levels with 100 μm resolution.
- Optional dual-reagent dispenser can be used for assays requiring precise timing such as ion channel assays or luminescent flash ATP assays.
- Comes with Gen5 software: reader control, advanced data analysis and flexible Excel export in one software package.
Model |
Synergy H1m |
|
Part # |
H1M |
H1MD |
Monochromator fluorescence |
• |
• |
Monochromator absorbance |
• |
• |
Luminescence |
• |
• |
Time-Resolved Fluorescence |
• * |
• * |
Dual reagent dispenser |
|
• |
Temperature control to 45°C |
• |
• |
Gen5 data analysis software |
• |
• |
* Secondary mode
| General | |
| Wavelength Selection | Quadruple Monochromators |
| Detection method | Fluorescence, Luminescence, UV-Visible Absorbance, TRF (secondary mode) |
| Read method | End-point, kinetic, spectral scanning, well-area scanning |
| Microplate types | 1- to 384-well plates Compatible with Take3 plate with 2 µL microspots |
| Maximum Plate Height | Absorbance: 0.8" (20.3 mm) Fluorescence & Luminescence: 0.89" (22.6 mm) |
| Temperature control | To 45°C +0.5°C at 37°C |
| Shaking | Yes |
| Software | Gen5™ reader control, advanced data analysis, Excel export Control through USB or serial port |
| Automation | Yes |
| Absorbance | |
| Light source | Xenon Flash Lamp |
| Wavelength selection | Monochromator |
| Wavelength range | 230 - 999 nm, 1 nm increment |
| Bandpass | 4 nm (230-285 m), 8 nm (>285 m) |
| Dynamic range | 0 - 4.0 OD |
| Resolution | 0.0001 OD |
| Pathlength correction | Yes |
| Monochromator wavelength accuracy | +2 nm |
| Monochromator wavelength repeatability | +0.2 nm |
| OD accuracy | <1% at 2.0 OD typical <3% at 3.0 OD typical |
| OD linearity | <1% from 0 to 3.0 OD typical |
| OD repeatability | <0.5% at 2.0 OD typical |
| Stray light | 0.03% at 230 nm typical |
| Reading speed | 96: 11 seconds 384: 22 seconds |
| Fluorescence Intensity | |
| Sensitivity | Fluorescein 2.5 pM typical (0.25 fmol/well 384-well plate) |
| Light source | Xenon Flash Lamp |
| Wavelength selection | Double grating monochromators (Top and Bottom) |
| Wavelength range | 250 – 700 nm (900 nm option) |
| Dynamic range | 5 decades |
| Detection system | Low noise PMT |
| Reading speed | 96: 11 seconds 384: 22 seconds |
| Luminescence | |
| Sensitivity | 20 amol ATP typical (flash) |
| Wavelength range | 300 - 700 nm |
| Dynamic range | >6 decades |
| Reagent Dispensers | |
| Dispense Precision | <2% at 50-200 µL |
| Dispense Accuracy | +1 µL or 2% |
| Number | 2 syringe pumps |
| Plate Geometry | 1- to 384-well microplates |
| Dispense volume | 5 - 1000 µL in 1 µL increment |
| Dead volume | 1 mL, 100 µL with back flush |
| Physical Characteristics | |
| Power | 130 Watts max |
| Dimensions | 15.4"W 18.6"D 12.9"H (39.1 x 47.2 x 32.8 cm) |
| Weight | 50 lbs (22.5 kg) |
| Regulatory | |
| Regulatory | All BioTek microplate instrumentation is CE and ETL marked. For details on approvals and standards compliance, please contact BioTek |
Specifications are subject to change.
Standard (Included)

Gen5 Data Analysis Software
Optional

BioStack Microplate Stacker
Standard (Included) | ||
Cables | ||
| 75034 | Serial Cable, Modem (9-pin female to 9-pin male) |
|
| 75108 | USB Cable (male A to male B) |
|
Operators Manual | ||
| MANUAL | Operator's manuals can be obtained via the Customer Resource Center | |
Optional | ||
Labware Holders | ||
| 7302030 | Cuvette Adapter |
|
Miscellaneous | ||
| 7270512 | BioCell Adapter Plate Assembly |
|
| 7272051 | BioCell 1 cm Quartz Vessel |
|
Take3 Micro-Volume Plate | ||
| TAKE3 | Take3 Micro-Volume Plate |
|
Test Plates & Reagents | ||
| 98155 | Sodium Fluorescein Powder (1 mg vial) |
|
| 7120779 | BioTek QC Check Solution #1 - Yellow (25 mL) |
|
| 7120782 | BioTek QC Check Solution #1 - Yellow (125 mL) |
|
| 7160006 | Glowell Adapter for Synergy Luminescence Tests |
|
| 7260522 | Absorbance Test Plate |
|
| 8030015 | Luminescence Test Plate |
|